Commissioning and Science Verification
Optical pointing > Optical telescope setup†
- What's this page?
- This page describes the way to setup the optical telescope for optical pointing measurements.
- Revision history
- 2006 - K. Nakanishi - prepared ASTE_OPT_FOCUS.pdf
- 2010-04-02 - N. UKITA - modified.
- 2010-09-03 - B. Hatsukade - created Pukiwiki pages from the PDF.
- 2013-08-05 - N. UKITA - modified.
- 2014-04-21 - BH and YW - updated.
- 2016-08-01 - Kamazaki,T. - modified for Linux COSMOS3.
 
- Table of contents
- 
Optical telescope setup†
- ASTE光学望遠鏡hardwareの立ち上げ手順
 &ref(): File not found: "ASTE_OPT_Get-Started_v2.pdf" at page "CSV/OpticalPointingOPTSetup";
Focus adjustment†
- ASTE光学望遠鏡ピント合わせ手順 (obsolete)
 &ref(): File not found: "ASTE_OPT_Focus.pdf" at page "CSV/OpticalPointingOPTSetup";
Display an optical image to check focusing†
- Login to COSMOS3 manager GUI with Group=asteXX (e.g. aste16) and Project=opttrk (Project = 'radpon' for 2016 season?; KT)
- Start an obstable (table with name starting with 't', eg. 't163-16C.start'; KT), which will just track a star continuously, in the project
- Login to the Mitaka analysis computer (e.g. aste-ms1) with asteXX (e.g. aste16)
% ssh -Y asteXX@aste-ms1 - Don't forget to add '-Y' option to forward windows.
 
- Initialize the video capture board (at the start of measurements once a day)
asteXX@aste-ms1: ssh astecntl@aste-c1c /cosmos3/naoj/sbinSol/optinit
device:    [ ok ]
mmap:      [ ok ]
init bcr:  [ ok ]
init:      [ ok ]
initLUT:   [ ok ]
clear FB:  [ ok ]
AVME-338B -> successfully initialized    <--- confirm this message 
- Display (a part of) an optical image
asteXX@aste-ms1: ~/analysis/bin/optshot.sh r  1  128
                                          (1)(2) (3)
(1) Frame color to be dumped (normally, 'r'=Red is used)
(2) Number of frames to be taken (set '-1' for infinite loop)
(3) Image size [pixel] (set '448' for a full-size image)
This will display an image whose center is (256, 256) pixels and size is 32 pixels.#ref(): File not found: "opt_optpon.png" at page "CSV/OpticalPointingOPTSetup" - A star would be close to the image center, if antenna pointing is appropriately adjusted.
- Pixel scale is 1.27 [arcsec/pixel].
 
Adjust focus position†
- Run a observation table just tracking a star
group: asteXX
project: opttrk
observation table: Select a table close to the current LST
e.g.) t132-36B.start for LST13h
       (1)(2)(3)
(1) R.A.
(2) Dec.
(3) Brightness (A>B>C>D)
    夜間Aの星はサチる可能性がある
- Login to aste-c1c with astecntl
> ssh astecntl@aste-c1c 
- Connect the stage controller
astecntl@aste-c1c: tip serial2
connected    <--- confirm this message for successful connection 
- Move the focus stage so as to achieve sharp image in OPT
- There is no command prompt
- Each command has to be followed by twice inputs of RETURN
- Input ~. to disconnect.
- Print status
Q:1  
1, +12345, ACK1, ACK2, ACK3
+12345: current position
ACK1 X: command error / K: command success
ACK2 K: stop successfully / P: stop due to '+' limit / M: stop due to '-' limit
ACK3 B: busy / R: ready 
- Move to the origin
H:1             ←原点設定(レンズ側の端を原点とする)
G               ←移動開始(10秒くらい待つ)
Q:1             ←ステイタス確認
1,         0,K,K,R       と表示されれば正常終了 
- Move (※画像が更新されるまでに時間がかかるので注意)
M:1+P20100      ←20100パルス分移動準備
G               ←移動開始
Q:1             ←ステイタス確認
1,         +20100,K,K,R  と表示されれば設定正常終了 ピントが大きくズレていると判断されたときには、数百パルス程度ステージを前後に動かしてみる。M:1+P500        ←+500パルス移動
G               ←移動開始
Q:1             ←ステータス確認
L:1             ←ステージを緊急停止させる 
 
History of focus positions†
Troubleshooting†
- Cannot login to aste-c1c
- Cannot initialize the capture board or take optical images
- No star in an optical image
- Make sure no auxiliary offset in dAZ and dEL. That is (dAZ, dEL) = (0.0, 0.0).
- Move the focus stage.
 
- Connection failures to the focus stage controller
- aste-c1cをrebootした直後は接続に失敗する場合が多いので、以下の対症療法を試してみてください(ほぼ百発百中)
 - rootになる
- admintoolを立ち上げる
- 「シリアルポートの設定」を選び
- term/2を選び、(ダイアログが開く)
- 設定変更をしないでOKボタンを押す (あるいは、適当に設定をいじるが最後は元に戻しOKボタン)
 - all ports busyが出た場合は tip のprocessをkillすることでも大丈夫
==>要確認
- キャビン(前室)に行って、ステージの電源を入れ直す (ラックの裏側のケーブルがやたらととぐろを巻いている中に、「光望遠鏡タップ」とか書いたケーブルがあり、100Vに差してあるはず。これを抜き差しすればよい)
- 電源を切ってもステージ位置は保存されます (ただしQ:1を送ったときに帰ってくる位置値は0になる。すなわち、原点(位置値=0)は、電源が入った時点でステージがあった位置に設定されてしまう←仕様)
 
- Focus stage: status error / command error
Q:1
1,         0,X,K,R 
コマンド入力の際、ステータスを読んでからパルス値を入力する前にリターンを2回押していない可能性がある。
- Focus stage: cannot display the status
Q:1