Commissioning and Science Verification

Subref position offsets for single-beam receivers > Measurement

Revision history
  • 2016-08-01 - Kamazaki,T. - created
Table of contents

Preparations

  1. Login to COSMOS3 manager GUI with Group=asteXX (e.g. aste16) and Project=sbrfXX (e.g. sbrf16)
  2. Tune the receiver to be used
  3. Check Aspirin is in the WIND ON mode
    • Aspirin status can be confirmed by looking at the Aspirin Monitor window. Check the following three items.
      Current time = 2016/09/02 08:22:15    <--- The differences among these three times
      Aspirin time = 2016/09/02 08:22:14    <--- should be less than 60 seconds.
      Weather time = 2016/09/02 08:22:08    <---
      Aspirin Offset : (Az, El) = (   6.64,   0.42 )
      Aspirin status : ** WIND ON ** ( C22:on  C6:OFF WIND:on )    <--- should be "WIND_ON"
      Refraction Corr. status : OK                                 <--- should be "OK"
  4. Launch CONT qlook (qlookc) from cos3launcher
    • Turn on auto-pointing
    • Push the START button

Measurement

  1. Adjust pointing [#bbb14ab6]
  1. Adjust focus [#fc7117c6]
  1. Run either of the following observation lists in the batch mode of the COSMOS3 manager GUI [#yfbf5e64]
     
    SaturnDASH345stsbd3.list
    BAND8stsbb8.list
     
    • A loop consists of 12 observation tables
      Step 1. repeat [z->a->b->c->d->e->a->f->g->h->i->a]
      
      z|
      -+
          e       A
          d       |X (dx=1.0 mm)
      g f a h i  <-Y (dy=1.0 mm)
          b
          c
    • Since data are reduced by a unit of the loop, stop running observations after the last observation table "a" if necessary

Front page   New Page list Search Recent changes   Help   RSS of recent changes