Commissioning and Science Verification

Radio pointing offsets for single-beam receivers > Measurement

Revision history
  • 2016-09-01 - Kamazaki,T. - created
Table of contents

Preparations

  1. Login to COSMOS3 manager GUI with Group=asteXX (e.g. aste16) and Project=sbrfXX (e.g. sbrf16)
  2. Tune the receiver to be used
  3. Check Aspirin is in the WIND ON mode
    • Aspirin status can be confirmed by looking at the Aspirin Monitor window. Check the following three items.
      Current time = 2016/09/02 08:22:15    <--- The differences among these three times
      Aspirin time = 2016/09/02 08:22:14    <--- should be less than 60 seconds.
      Weather time = 2016/09/02 08:22:08    <---
      Aspirin Offset : (Az, El) = (   6.64,   0.42 )
      Aspirin status : ** WIND ON ** ( C22:on  C6:OFF WIND:on )    <--- should be "WIND_ON"
      Refraction Corr. status : OK                                 <--- should be "OK"
  4. Launch CONT qlook (qlookc) from cos3launcher
    • Make sure auto-pointing is disabled
    • Push the START button
  5. Adjust pointing using either of the following observation tables
     
    SaturnDASH345stx5d3.start
    BAND8stx5b8.start
  6. Run either of the following observation lists in the batch mode of the COSMOS3 manager GUI
     
    SaturnDASH345stsbd3.list
    BAND8stsbb8.list
     

1. Aspirin is running on aste-1c

2. (dAz, dEL) is (0.0, 0.0)

3. OPT image

4. Start iOPT on aste-c1c

Measurement

  1. Check list
    • Check Aspirin is in the WIND ON mode
  1. Start COSMOS3 and tune the receiver to be used

Front page   New Page list Search Recent changes   Help   RSS of recent changes