Commissioning and Science Verification

Optical Pointing > Preparation at the ASTE site

What's this page?
This page is prepared for optical pointing to determine global pointing parameters.
Revision history
  • 2006 - ASTE_OPT_FOCUS.pdf K. Nakanishi
  • 2010-04-02 - modified by N. UKITA
  • 2010-09-03 - moved to Pukiwiki by B. Hatsukade
  • 2013-08-05 - modified by N. UKITA
  • 2014-04-21 - updated by BH and YW
  • 2016-07-25 - modified for Linux COSMOS3 by Kamazaki,T.
Table of contents

Setup the optical telescope

Focus adjustment

Display an optical image to check focusing

  1. Login to aste-c1c with asteXX
    > ssh asteXX@aste-c1c
    (Direct login is available from aste-mt1 and aste-ms1.)
  2. Initialize the video capture board (at the start of measurements once a day)
    asteXX@aste-c1c> /cosmos3/naoj/binSol/optinit
    device:    [ ok ]
    mmap:      [ ok ]
    init bcr:  [ ok ]
    init:      [ ok ]
    initLUT:   [ ok ]
    clear FB:  [ ok ]
    AVME-338B -> successfully initialized  <- should be returned
  1. Display (a part of) an optical image
    asteXX@aste-c1c> livecamt R 30 15 256 256 40 
                             (1)(2)(3)(4) (5) (6)
    (1)おまじない
    (2)取り込みフレーム数
    (3)取り込み間隔
    (4,5)切り出すフレームの中心(X,Y)
    (6)切り出すフレームサイズ
    「(X,Y)=(256,256)を中心とする40x40ピクセルの部分画像を表示、30フレーム連続取り込み(表示)、取り込み間隔は15秒 」

#ref(): File not found: "t195.jpg" at page "CSV/OpticalPointingPreparation"

Adjust the focus stage position

  1. Run a observation table just tracking a star
    group: asteXX
    project: track
    observation table: Select a table close to the current LST
    e.g.) t132-36B.start for LST13h
           (1)(2)(3)
    (1) R.A.
    (2) Dec.
    (3) Brightness (A>B>C>D)
        夜間Aの星はサチる可能性がある
  2. Login to aste-c1c
  3. Connect the stage controller
    asteXX@aste-c1c> tip serial2

"connected" と表示されたら接続成功

※ 接続に失敗した場合

  1. rootになる
  2. admintoolを立ち上げる
  3. 「シリアルポートの設定」を選び
  4. term/2を選び、(ダイアログが開く)
  5. 設定変更をしないでOKボタンを押す (あるいは、適当に設定をいじるが最後は元に戻しOKボタン)

3. コマンドを逐次入力

History of focus positions

2003-0413700(参考値)外気温0+-5°Cでの最適値(赤フィルターなし)
2009-0720100近辺Observing Log/2009-07-29
2010-0421100Observing Log/2010-04-12
2010-090Observing Log/2010-09-09
2011-04-500Observing Log/2011-04-14
2012-0620700Observing Log/2012-06-15
2014-0420500Observing Log/2014-04-21

Troubleshooting

コマンド入力の際、ステータスを読んでからパルス値を入力する前にリターンを2回押していない可能性がある。


Front page   New Page list Search Recent changes   Help   RSS of recent changes