[[Observing Log]] ---- #contents ---- * CSV2016: Preparations (2016-08-10) [#pfe43f53] ** Tasks [#vef4ebed] - Continuum observation testing -- Test observation tables -- Make sure that Saturn can be detected - Optical telescope testing -- Test global optical pointing ---- ** Information [#w1934f81] - Observers: Kamazaki - Site: Mitaka - Weather conditions (2016-08-09T23:50) Temperature: -5.4 C Humidity: 0.9 hPa Wind: 5.1 m/s, 284 deg 220GHz opacity: 0.06 ** Continuum observation testing [#ff3aa886] - Summary of the Qlookc issue (no plotting) by Horigome-san [fjaste 00093] -- If time has passed 1 hour without CONT observations after taking the control priority, the firewall of NAOJ could cut Qlookc connections between the ASTE site and a local site due to no network traffic. -- Qlookc cannot get any data from the ASTE site under such the disconnected situation, and nothing is plotted. -- Its recovery way is to restart qlookc relevant processes on the ASTE site and a local site. (Its actual way needs to be confirmed.) -- It is necessary to push the START button on Qlookc before starting a new observation. - Successful Qlookc plots -- I confirmed Qlookc plots by starting a new observation just after taking the priority and pushing the START button on Qlookc. - Continuum observation tables -- The following observation tables succeeded in running. Directory: aste16/sbrf16 Observation tables: str05d3.start: raster mapping stx5d3.start: cross scan stsbd3z.start: on-source tracking for z-axis measurements stsbd3a.start, stsbd3b.start, stsbd3h.start: cross scan for xy-axis measurements --- Group/Project: aste16/sbrf16 --- str05d3.start: raster mapping --- stx5d3.start: cross scan --- stsbd3z.start: on-source tracking for z-axis measurements --- stsbd3a.start, stsbd3b.start, stsbd3h.start: cross scan for xy-axis measurements ** Optical telescope testing [#i94bb1de] - Global optical pointing -- iOPT_r17shm tests --- LST00h00m.start successfully ran and iOPT_r17shm output 201608xx.tab. --- LST00h00m.start successfully ran and iOPT_r17shm output 201608100656.tab. --- Quick data reduction shows reasonable results.