YuhangZhao - 19:01, Wednesday 06 June 2018 (800)Get code to link to this report
recheck of laser parameter

Since we find the beam parameter changed because we change the laser power, we did the beam parameter measurement again. Now the power of laser is 277mW.

from laser head cm

beam diameter1 um beam diameter2 um
34 1975 1848
29 1801 1683
24 1643 1527
19 1421 1371
14 1274 1194

result 1: 183um at -0.19m

result 2: 201um at -0.20m

mean: 192um at -0.195m

Comments related to this report
EleonoraCapocasa - 11:46, Thursday 07 June 2018 (802)

This is for AUX 1, the laser that will be used for the coherent control. A first characterization was done and reported in entry 666. It seems compatible with the new measurement.