laser : 7 A and HWP = 0deg : ~30mW
surface calib
z_iu = 69.18mm
z = 33 mm, (x,y) = (327.093,119.965)
checked calibration factor from 33 to 36mm, the max is at z=35mm ~13.9/W
z scan : Fri, Mar 29, 2024 11-29-17 AM.txt with Pt = 20.8mW (Pt = 21.4mW corresponds to Pin = 31.4mW)
bulk calibration
Pin = 31.1mW, Pt = 17.1mW to compute transmission
during measurement Pt = 17.5mW
moved z_iu by -0.32mm, z = 33.8mm gives R = 0.6413cm/W
z scan : Fri, Mar 29, 2024 2-27-42 PM.txt
T50#1 (30mm diameter, 50mm length, #4/6)
ziu = 48.61mm
dc was heavily misaligned in vertical... due to holder?
check if center is (x,y) 327,119 we can do +/-10mm in all direction without problem
also dc does not change during this so holder seems fine
Pt = 26.6mW, Pin = 31.2mW
can change z between 20 to 90 mm
HWP = 28deg : Pt = 4.83W
long z scan at x,y center : Fri, Mar 29, 2024 5-33-48 PM.txt
z edges are at 26 and 60 mm :Z_center = 43mm
10 mm radius map at z_center with 5mV gain and Pt = 4.81W : Fri, Mar 29, 2024 6-53-59 PM.txt
I placed a pink tape on top close to IU side
pt _ 4.65W
map at z_53 mm , Pt _ 4.65W; Sat, Mar 30, 2024 11-35-05 AM.txt
map at 33mm ' Sat, Mar 30, 2024 8-01-36 PM.txt