NAOJ GW Elog Logbook 3.2
Displaying report 1-1 of 1.
YuhangZhao - 16:29, Wednesday 05 October 2022 (3080)
Measurement of sqz/asqz when pump power is scanned
Measurement conditions:
MZ 4.6, CC1 44.4 temp 7.165, sqz 110, asqz 160
MZ 4.7, CC1 51.2 temp 7.172, sqz 125, asqz 180
MZ 4.4, temp 7.163, sqz 110, asqz 150
Measurement results:
sqz: 5.41, 6.34, 6.03
asqz: 10.84, 14.63, 16.64
Images attached to this report
Comments related to this report
The extracted optical losses and phase noise are 22.51+/-3.49 % and 8.88 +/- 55.25 mrad.
The error bar for phase noise is very large since points are scattered around the fitted curve. Either more precise measurement or more points would help to reduce the error bar.