MichaelPage - 02:54, Friday 27 May 2022 (2961)

Squeezer p-pol
I couldn't find the p-pol laser and sidebands on the spectrum analyser (figure 1). I made sure the DDS board was reset properly, the lasers had proper current and temperature, and the beam was going into the fiber. I also tried disconnecting and reconnecting p-pol cables that I could see. Maybe something is disconnected elsewhere?
CC seems ok (figure 2)
Images attached to this report
Comments related to this report
The beatnote can be seen with lower reference level (10dBm) as shown in the attached picture.