R&D (FilterCavity)
Print this report.
YuhangZhao - 19:17, Sunday 04 July 2021 (2608)Get code to link to this report
New filter for filter cavity z-correction

It was noticed that filter cavity z-correction was feeding back some high frequency components recently.

I modified the filters and now less high frequency components are feed to end mirror.

The new filter is called dc_damp2 (gain is adjusted so that we can use gain 1 in medm). Let's use this filter in the future.

Poles: 1e-4, 0.1(1), 20, 20, 300

Zeros: 0.04, 0.05(1), 3

The comparison of signal sent to end mirror is attached.

Images attached to this report
2608_20210704121700_newzcorr.png