Warning: Undefined variable $s in /wwwsto01/wwwusers/gw-elog/osl/classes/DAO.php on line 959
NAOJ GW Elog Logbook
LOG-IN
Displaying report 1-1 of 1.
R&D (FilterCavity)
Print this report.
YuhangZhao - 12:13, Sunday 20 June 2021 (2590)Get code to link to this report
A long-term monitor of AOM frequency

To understand how stable the GR lock can provide for the detuning, I would propose the record AOM frequency few times one day. And up to few days or weeks at least.

Note: we should try to not change alignment condition and use the same pointing.

1. 2021/06/20 12:10 109.538080MHz

2. 2021/06/21 09:20 109.538070MHz

3. 2021/06/21 14:21 109.538070MHz

4. 2021/06/21 21:37 109.538060MHz

5. 2021/06/22 09:27 109.538070MHz

6. 2021/06/22 13:29 109.538075MHz

7. 2021/06/22 15:53 109.538065MHz

8. 2021/06/23 09:07 109.538055MHz

9. 2021/06/23 13:27 109.538055MHz

10. 2021/06/23 21:40 109.538064MHz

11. 2021/06/24 09:53 109.538066MHz

12. 2021/06/24 13:53 109.538070MHz

13. 2021/06/24 20:02 109.538060MHz

14. 2021/06/25 16:06 109.538060MHz

15. 2021/06/25 19:02 109.538050MHz

16. 2021/06/26 10:37 109.538047MHz

17. 2021/06/26 20:06 109.538040MHz

18. 2021/06/27 11:04 109.538045MHz

19. 2021/06/27 19:21 109.538030MHz

20. 2021/06/28 10:01 109.538050MHz

21. 2021/06/28 15:00 109.538020MHz

22. 2021/06/28 22:00 109.537910MHz

23. 2021/06/29 15:59 109.538030MHz

24. 2021/06/30 09:56 109.538070MHz

25. 2021/06/30 20:19 109.538060MHz

26. 2021/07/1 11:01 109.538065MHz

27. 2021/07/1 20:12 109.538065MHz

28. 2021/07/2 08:54 109.538060MHz

29. 2021/07/2 20:06 109.538030MHz

30. 2021/07/3 07:06 109.538024MHz

31. 2021/07/4 09:29 109.538060MHz

32. 2021/07/5 16:37 109.538050MHz

33. 2021/07/6 10:23 109.538030MHz

Comments related to this report
YuhangZhao - 11:56, Monday 28 June 2021 (2604)

In the last week, resonant condition between GR and IR changed by around 20Hz.

To check if there is any correlation with suspended mirrors, I checked the oplev signal of all mirrors. Basically all mirrors are staying in the same orientiation, but end mirrors have quite obvious drift during the last week. In fact, this drift seems to be not really because we are not really correcting it by the coils. So we need to investigate why end mirror oplev is behaving like this.