R&D (FilterCavity)
YuhangZhao - 13:31, Wednesday 08 August 2018 (937)
Comment to Green beam reflected by the FC (Click here to view original report: 935)

I  used ABCD matrix to calculate the beam parameter before the lens(the lens used to perform better beam measurement). The result is as following:

beam waist position: -3.2m (relative to Faraday Isolator)

beam waist size: 877.20um

I also attached the python code, if you are interested, please have a look.

Non-image files attached to this comment