R&D (FilterCavity)
MatteoLeonardi - 14:35, Wednesday 01 November 2017 (578)
telescope local control
This entry reports some features of the status of the telescope local control (PR and BS) as it was October, 30th 2017.
In the first picture the error signals and correction signals for PR.
In the second picture the error signals and correction signals for BS.
The resitual motion with the loop closed are:
  [urad]
PR yaw 0.78
PR pitch 1.40
BS yaw 2.21
BS pitch 4.31

The reference for the residual motion can be found in the previus entry n.428

Images attached to this report
578_20171101063442_prlocalcontrol.jpg 578_20171101063448_bslocalcontrol.jpg