[Marc, YokozaWashimi]
We performed the hammering test for the FC optics, to investigate the origin of the 170Hz noise.
50n Hz peaks are AC power and its harmonics.
The Eigen frequencies of the optics are higher.
The most suspicious object was the chamber.