KAGRA MIR (Polarization)
MarcEisenmann - 20:06, Monday 18 October 2021 (2714)
birefringence measurement of AZTEC sample rotated by 180 deg

During the week-end we took birefringence measurements of the AZTEC sample rotated by 180 deg and back to same orientation as the absorption measurement (ie 0 deg).

Due to some mistakes it was not possible to perform too many measurements (once labview is exited it reset the lockin amplfiier to absorption measurement)..

To avoid confusion I report here the measurement with 180 deg rotation.

Images attached to this report
2714_20211018130535_0deg.png 2714_20211018130539_45deg.png 2714_20211018130543_64deg.png 2714_20211018130547_70deg.png 2714_20211018130554_polarela.png 2714_20211018130559_s0.png 2714_20211018130603_s1.png 2714_20211018130607_theta.png 2714_20211018130610_deltan.png 2714_20211018130613_meandeltantheta.png