Comment to A comparison of fitting FDS from our published result (Click here to view original report: 2620)

The mcmc fit result of four parameters from published FDS data

  sqz (dB) loss (%) phi (deg) det (Hz)
1 8.3 +0.5/-0.3 34.1 +1.0/-0.8 0.1 +0.4/-0.5 46.3 +1.8/-2.1
2 8.2 +0.5/-0.5 36.0 +1.5/-1.9 14.7 +0.9/-0.8 68.7 +2.7/-2.6
3 8.9 +0.1/-0.2 34.4 +0.5/-0.3 26.0 +0.4/-0.3 59.8 +0.9/-0.7
4 7.8 +0.4/-0.3 40.1 +0.7/-1.3 43.3 +1.8/-2.1 66.0 +2.4/-2.9
5 8.9 +0.1/-0.1 34.2 +1.9/-0.9 55.4 +1.7/-1.0 63.6 +1.9/-1.2
6 8.6 +0.2/-0.2 36.7 +2.9/-2.5 91.6 +1.8/-2.0 70.9 +1.6/-1.9