R&D (FilterCavity)
YuhangZhao - 14:39, Thursday 15 July 2021 (2621)
Comment to A comparison of fitting FDS from our published result (Click here to view original report: 2618)

For detuning around 200Hz data, the fit result of generated squeezing level and optical losses are

  sqz loss
data1 11.1 38.3
data2 11.2 39.9
data3 11.1 39.9
data4 10.8 37.4
data5 10.6 37
data6 10.5 42

For detuning around 70Hz data, the fit result of generated squeezing level and optical losses are

  sqz loss
data1 10.7 40.6
data2 10.4 40.6
data3 10.4 40.4
data4 10.0 37.5
data5 9.6 36.8
data6 10.0 37.1