R&D (FilterCavity)
YuhangZhao - 03:06, Saturday 19 September 2020 (2218)
Open loop transfer function of AA (four loops: input p/y and end p/y)

Aritomi and Yuhang

The transfer function of each control loop was measured. The measurement was done with the excitation and the channel before and after that.

The control loop for yaw has unity gain frequency around 0.2Hz.

But the control loop for pitch has unity gain frequency less than 0.1Hz.

Images attached to this report
2218_20200918200826_inputpit1.png 2218_20200918200832_inputyaw1.png 2218_20200918200848_endpit1.png 2218_20200918200854_endyaw1.png