R&D (FilterCavity)
EleonoraCapocasa - 19:37, Wednesday 30 October 2019 (1782)
Top coil of input mirror fixed

On Tue 29/11 we open INPUT vacuum chamber. Takahashi-san found the wire to the ground pin of the circuit of the top coil was broken. See picture.

He repaired it. We closed the chamber and check the the coil is working fine now.

Images attached to this report
1782_20191030113743_in4.jpeg