R&D (FilterCavity)
YuhangZhao - 10:24, Tuesday 24 September 2019 (1654)
Green filter cavity injection beam height adjustment for astigmatism

Yuefan and Yuhang

We found the beam height of the green beam between SHG and filter cavity has very large beam height change after the work of beam center on each lens.

We measured the beam height at several points. (The beam height at Faraday isolator is a very important parameter. We may send a tilted beam if the beam height is wrong. Also, Astigmatism beam could be cut if the beam is not center in this FI.)

position(holes) height(mm) height(mm) after adjustment
4.5 before lens2 77.5  
1.5 before lens2 77  
3 before EOM 76  
2 after EOM 74  
between two steering mirrors after EOM 74.5  
2 after lens3 76 75.5
3 after lens3 76.5 75.5
2 after AOM 78 76
5.5 after lens4 76 76.5
6.5after lens 4 76 76.5
10.5 after lens 4 73 76.5
1 after lens 5 74 76.5
1 after FI 74.5 76
1 before last steering 74 75.5
2 after last steering 76 75.5

Note: Lens1~5 is the lens in the sequance from SHG to PR chamber. (Details are also shown in the attached figure 1)

We also checked the beam shape. Attached picture 2: beam shape after AOM. Attached picture 3: beam shape before injection to PR chamber (magnified by a 50mm lens). Attached picture 4: beam shape seen at the end camera. Attached picture 5: reflected beam shape seen before FI.

We measured the beam parameter and fit with basic Gaussian beam function before and after today's work. The comparison is attached in the last two figures.

Images attached to this report
1654_20190924032228_2449420449222702925520190924102135.jpg 1654_20190924032250_2449420449222702925520190924102158.jpg 1654_20190924032333_2449420449222702925520190924102153.jpg 1654_20190924032338_2449420449222702925520190924102146.jpg 1654_20190924032343_2449420449222702925520190924102203.jpg 1654_20190924032601_figure09192.png 1654_20190924035255_figure0920.png