R&D (FilterCavity)
YuhangZhao - 22:04, Thursday 01 August 2019 (1543)
An abnormal behavior of CC2 control loop

[Yuhang and Aritomi]

We tried to use different control bandwidth for CC2 locking. But the measurement result shows not a very reasonable result.

Usually, the higher the bandwidth the better control. However, we are not having this situation now. But it can also be related to the not well-designed control loop.

Images attached to this report
1543_20190801150347_ccphase.png 1543_20190801150359_sqz.png